Beam200 Series Single-ended Reflected Type Beam Smoke Detector

Kingfisher Model BEAM200 is an intelligent projected beam smoke detector. It is uniquely suited for protecting open areas with high ceilings where other methods of smoke detection are difficult to install and maintain. It is to be used with KCi compatible control panels only. Installation of the single-ended reflective design is much easier than dual ended projected beam detectors. Alignment is quickly accomplished via an optical sight and a 2-digit signal strength meter incorporated into the product. Listed for operation from –22°F to 131°F, BEAM200 can be used in open area applications to provide early warning in environments where temperature extremes exceed the capability of other types of smoke detection.

BEAM200S is equipped with an integral sensitivity test feature that consists of a test filter attached to a servo motor inside the detector optics. Using the remote test station RTS451, the motor is activated and moves the filter in the pathway of the light beam, thereby testing detector sensitivity. This integral sensitivity test feature allows the user to quickly and easily meet the annual maintenance and test requirements of NFPA 72.

Spec Sheet

FX2003RT Intelligent Analog Fire Alarm Control Panel with Radio Transmitter

The FX-2003/RT Intelligent Analog Fire Alarm Control Panel with Radio Transmitter is designed to provide maximum flexibility of analog radio communication system while also providing easy installation and operation at a cost-effective price.

The FX-2003/RT base panel consists of one intelligent analog loop controller capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4). The system can be expanded by adding additional Analog Loop Controller Modules which allows up to 8 addressable circuits loops w/99 sensors per loop. In addition the base panel supports 16 conventional hardwire adder modules such as the DM-1008A Initiating Circuit Module, KFSGM-1004A Indicating Circuit Module and the KFRM-1008A Relay Circuit Module.

Additional conventional hardwire adder modules can be added with the KFALC-H16 Adder Hardwire Loop Controller Module, which allows the system to support an additional 16 conventional adder modules. The base panel also consists of 4 Class A/B (Style Z/Y) Indicating Circuits rated at 1.7 Amps each and either a 6 or 12 Amp Power Supply.

The FX-2003/RT panel also provides the most reliable and efficient means of transmitting radio coded alarm and trouble signals to an Emergency Service Dispatch Center having a KFRA-C radio fire alarm receiver(s) up to 25 miles away.

Equipped with a large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2003/RT utilizes a simple Menu system complete with a directional keypad, common control switches and LEDs, Alarm Queue switches and LEDs, two configurable input switches and 16 configurable zone LEDs.

Spec Sheet

IPS-2424 Programmable Input Switch Module

The IPS-2424 Programmable Input Switch Module, which provides 24 programmable switches complete with bi-colored LEDs and slide in labels, can be configured for auxiliary functions such as zone by-pass or added common control functions. In a zone bypass configuration, a group of addressable devices or hardwired circuits can be assigned to a programmable switch and when the switch is operated, those devices or zones are by-passed. The switches operate in an alternating toggle operation for on and off. There are two LEDs for each switch; one for selection, the other is bi-colored to indicate point status when the switch is returned to normal (un by passed) position. The bi-colored LED will flash red to indicate an alarm or it will flash amber to indicate that a trouble alarm will be processed when the switch is returned to normal (un by passed) position.

The IPS-2424 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if unique programmable input switches are required for a specific location. The IPS-2424 takes up two frames when connected to the main or remote shared display. The IPS-2424 occupies one display position in the BB-1000 or BB-5000 enclosures.

Spec Sheet

KF200 Intelligent Low Profile Plug-in Detectors

The KF200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel.

Point ID capability allows each detector's address to be set with rotary address switches. This provides exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level.

Spec Sheet

Dual Monitor Module KF500DM

The Intelligent Addressable Dual Monitor Module (KF500DM) provides two independent 2-wire initiating device circuits at two separate, consecutive addresses. It is capable of monitoring two separate Class B (Style B) circuits simultaneously, making it ideal for water flow and tamper switch monitoring. The KF500DM has a single activated red LED that is common to either circuit.

Spec Sheet

KF500X Fault Isolator Module

The KF500X Fault Isolator Modules enable part of the communications loop to continue operating when a short circuit occurs on it. An LED indicator blinks in the normal condition and turns on during a short circuit condition. The module will automatically restore the entire communications loop to the normal condition when the short circuit is removed.

Spec Sheet

KF502M Zone Interface Module

The KF502M provides the same features as the KF500M for the FX2003 Fire Alarm Panel but also allows for the use of multiple, conventional 2-wire smoke detectors in the circuit. This module requires a resettable signal power source. The KF502M internally supervises the separate power source. The red LED indicates when the module is activated. All two-wire detectors that are monitored must be UL compatible with the KF502M module.

Spec Sheet

KF710ADU Addressable Manual Pull Station Dual Action

The KF710ADU Pull Station provides Manual fire reporting. This high quality, die-cast metal Intelligent Fire Alarm Pull Station is available in a dual action configurations with a permanently attached addressable module.

The KF710ADU Pull Station is available with a CAT-211 key and mounts on a standard single gang backbox or model KFBB-700 interior surface metal backbox.

The KF710ADU addressable pull station has a pair of rotary decimal switches which allows for two digit address setting. Pulling the handle initiates the operation of the addressable module.

Spec Sheet

KF2251TMB Intelligent Multi-Criteria Sensor

Kingfisher Company inc.'s, Intelligent Multi-Criteria Sensor uses advanced software to continuously sample the air in an environment and adjust its detection parameters and alarm threshold accordingly. It does this automatically, without user intervention. There's no need for an installer to set sensitivity levels at the control panel – the KF2251TMB makes the educated decisions. The Multi-criteria Detection Reduces Nuisance Alarms.

Kingfisher Company inc.'s, multi-criteria sensor, is an intelligent sensor in more ways than one. First, it incorporates both thermal and photoelectric technologies that interact to maximize detection. Second, an onboard microprocessor and advanced software focus on rejecting nuisance alarms.

A patented photoelectric sensing chamber and dual thermistor heat detector combine with an array of onboard software tools, to maximize fire detection.

In a real fire, the smoke and heat sensors work together to make the quickest possible decision. The photo sensor is optimized for smoldering fires, the heat sensors provide a faster response to flaming fires. A dual stage drift compensation feature reduces maintenance frequency.

The KF225TMB offsets the effects of gradual dust build-up and will notify the control panel before its compensation level is reached, allowing time for maintenance. Once the compensation limit is reached, a second signal is sent to the control panel indicating an urgent need for maintenance.

Spec Sheet

KFALC-198S Analog Single Loop Module

The KFALC-198S Single Analog Loop Controller Module provides an additional analog loop to the FX-2003 consisting of 99 Analog Sensors and 99 Addressable Modules. The KFALC-198S occupies one module slot in the FX-2003 main or expander chassis.

Spec Sheet

KFALC-396S Dual Intelligent Analog Loop Controller Module

The KFALC-396S Dual Analog Loop Controller Module provides two additional analog loops to the FX-2003 consisting of 99 Analog Sensors and 99 Addressable Modules per loop.

Spec Sheet

KFALC-H16 Hardwired Loop Controller Module

The KFALC-H16 Hardwire Loop Controller Module allows the FX-2003 Series to support an additional sixteen (16) conventional hardwire adder modules. The hardwire modules consist of the KFDM-1008 Eight Initiating Circuit Module, KFSGM-1004 Four Indicating Circuit Module and the KFRM-1008 Eight Relay Circuit Module. The KFALCH16 occupies one module slot in the FX-2003 Series main or expander chassis.

Spec Sheet

KFDM-1008A 8 Initiating Circuit Module

The Kingfisher Company, inc., KFDM-1008A Module provides the FX-2003 R/T Series Fire Alarm Control panels with up to 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits which can be configured for Alarm, Supervisory, Waterflow or Trouble circuits.

The KFDM-1008A provides up to eight zones of Class B (Style B) or four Class A (Style D) Initiating circuits. Each of the circuits can be configured as either Alarm, Supervisory, Waterflow or Trouble zones. Each circuit can handle both powered devices such as smoke detectors and non-powered devices such as heat detectors, pull stations, waterflow devices, tamper switches, etc.

Spec Sheet

KFDNR Intelligent Non-Relay Photoelectric Duct Smoke Detector

The KFDNR and KFDNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. The KFDNR and KFDNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexibility and installation ease.

These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of −4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the KFDNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, rain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money.

The KFDNR housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover.

The housing also provides a ¾-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring.

Spec Sheet

KFFDX-008 Fan Damper Control

The KFFDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green "run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. The KFFDX-008 connects to the main panel or the KFRAX-LCD when mounted remotely. It uses KFM500R or KFM500S for control of fans or dampers and two KFM501or KFM500Mfor status. The KFFDX-008 occupies one display position in the BB-1000 or BB-5000 enclosures.

Spec Sheet

Fire Fighter's Phone Jack, Handset, and Storage Cabinet

Kingfisher's Fire Fighter Telephones are designed to operate in conjunction with Kingfisher's KFQX-5000 Series Emergency Zoned Audio System. These telephone handsets are permanently installed throughout a building to allow Fire Fighters easy communication with the main control panel.

Kingfisher provides portable Fire Fighter telephone handsets which plug-in to permanently installed telephone jacks throughout the building. Plugging in the portable handset allows the Fire Fighters to communicate with the main control panel. As with the permanently installed telephones, these portable handsets are made from durable ABS plastic and come equipped with a coiled cord and a male phone plug which plugs into the Fire Fighters' telephone jack. In addition, an optional handset storage cabinet is available to store up to six portable handsets. An optional flush trim ring is available for the storage cabinet.

Spec Sheet

KFM500M Intelligent Addressable Monitor Module

The Kingfisher Company, inc., KFM500M, Intelligent Addressable Monitor Module provides an address for a group of UL/ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, water-flow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The KFM500M has an activated red LED.

The KFM500M Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary decade switches. It provides either a 2-wire or 4 -wire fault tolerant initiating circuit for normally open contact fire alarm, supervisory, or security devices. The module has a panel controlled LED indicator.

Spec Sheet

KFM500S Intelligent Addressable Supervised Control Module

The Kingfisher Company, inc., KFM500S Supervised Control Module provides supervised monitoring of wiring to load devices that require an external power supply to operate, such as horns, strobes, or bells. It is capable of Class A and Class B supervision. KFM500S Supervised Control Modules are intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary decade switches.

This module is used to switch an external power supply, which can be a DC power supply or an audio amplifier (up to 80 VRMS), to notification appliances. The KFM500S also supervises the wiring to the connected loads and reports their status to the panel as NORMAL, OPEN, or SHORT CIRCUIT. The KFM500S has two pairs of output termination points available for fault-tolerant wiring and a panel-controlled LED indicator.

Spec Sheet

KFM501M Intelligent Addressable Mini Monitor Module

The Kingfisher Company, inc., KFM501M Mini– Monitor Module provides an address for a group of UL Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, water flow switches, manual pull stations, etc. wired in a Class B (Style B) initiating circuit.

The KFM501M can be installed in a single gang junction box directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting.

The KFM501M is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary decade switches. It provides a two-wire initiating circuit for normally open contact fire alarm and security devices.

Spec Sheet

KFMGD-32 Master Graphic Driver Board

The MGD-32 Master Graphic Driver Module with the FX2000 Series Fire Alarm Panel provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. Any or all of these switch inputs can be used. There are supervised outputs for all of the support LEDs and the common control switches. The MGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps.

Spec Sheet

KFPR-300 Polarity Reversal Module

The KFPR-300 with the FX2000 Series Fire Alarm Panel provides outputs for city box and polarity reversal applications. The KFPR-300 provides off-premises signal transmission for systems that must comply with NFPA requirements for Auxiliary Protective Systems.

Spec Sheet

FX2003R/T Remote Annunciators KFRAX-LCD / KFRAX-1048

The KFRAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the FX2003 R/T panel, less 16 zone LEDs. It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display which uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. It also has 4 Alarm switches and LEDs as well as common control switches and LEDs for Signal Silence, Fire Drill, System Reset, Lamp Test, General Alarm and Acknowledge. The KFRAX-LCD can be programmed to show different points than the main panel. In addition to being a remote annunciator, the KFRAX-LCD can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with their unique configuration and fan damper control also with their unique configuration.

Each time a different type of annunciation configuration is required or a different location is required an additional KFRAX-LCD will be needed. The KFRAX-LCD allows for the control switches to be disabled on a per function basis (via laptop configurator) for areas that do not require certain Common Control functions to be remotely located from the Fire Alarm Control Panel. The KFRAX-LCD occupies one display position in the KFBB-1000 or KFBB-5000 enclosures.


The KFRAX-1048 Programmable Zone LED Annunciator Module provides 48 programmable bi-colored LEDs. The KFRAX-1048 is used if additional LED zone annunciation is required. The addressable points can be grouped together to light one LED, or they can be part of many groups and therefore may turn on many LEDs. The circuits can be selected as either Alarm to illuminate the red LED or for Supervisory to illuminate the amber LED. Any zone trouble condition will be displayed on the Shared Display. The KFRAX-1048 can be connected to the main panel or it can be connected to the KFRAX-LCD Remote Shared Display if a programmable remote LED annunciator is required. It takes up two frames when connected to either the main or remote shared display. The KFRAX-1048 is used in conjunction with the KFRAX-LCD when a different type of annunciation configuration or a different location is required. The KFRAX-1048 occupies one display position in the KFBB-1000 or KFBB-5000 enclosures.

Spec Sheet

KFRM-1008A 8 Relay Adder Module

The KFRM-1008A provides the FX-2003R/T with 8 individual configurable relays per module.

Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load). The KFRM-1008A occupies one module slot in the FX-2003 R/T main or expander chassis.

Spec Sheet

KFSGM-1004A 4 Indicating Zone Module

The KFSGM-1004A is a 4 Indicating Zone Module used with the FX2003 Series Fire Alarm Panel providing 4 Class A/B (Style Z/Y) Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuit is rated at 1.7 Amps. Each of the indicating circuits have individual LED indicator for status verification.

Spec Sheet

Multiple Input and Output Modules

The 500 Series multiple input and output modules are designed to meet a range of applications in which numerous single modules are used. This design allows for installation ease and time savings. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. The conventional zone interface module is ideal for retrofit applications to monitor zones of conventional two-wire detectors. Each module has its own address. Modules are addressed with easy-to-use rotary code switches. Provisions are included for disabling unused addresses. Up to two modules mount in a BB-2 enclosure with built-in chassis and up to six modules mount in a BB-6 enclosure with the CH-6 chassis. Wiring terminals are easily accessible for trouble-shooting purposes.

Spec Sheet

RAX-048 Programmable Zone LED Annunciator Module

The RAX-048 Programmable Zone LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-048 is used if additional LED zone annunciation is required. The addressable points can be grouped together to light one LED, or they can be part of many groups and therefore may turn on many LEDs. The circuits can be selected as either Alarm to illuminate the red LED or for Supervisory to illuminate the amber LED. Any zone trouble condition will be displayed on the Shared Display. The RAX-048 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if a programmable remote LED annunciator is required. When configured in this manner, it requires two frames when connected to either the main or remote shared display.

The RAX-048 is used in conjunction with the RAX-LCD when a different type of annunciation configuration or a different location is required. The RAX-048 occupies one display position in the BB-1000 or BB-5000 enclosures.

Spec Sheet

Contact Us